Herunterladen Diese Seite drucken

ims PRO SPOT 14500 TRAFO PRO Bedienungsanleitung Seite 41

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Insufficient air pressure
SPOT COUNT
If the caps are not changed after the warning message is displayed and the count is simply reset, they can deteriorate and have a negative
impact on the quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings» menu.
If the identification mode is switched off, il suffit de saisir un nom de rapport et de l'activer pour mémoriser les points de soudure effectués.
The log allows to store the parameters of the spots made using the clamp. It is available in all the modes by pressing the 2 buttons
The user program is available in all modes by pressing the
Report (log)
The log created contains: an ID entered by the user, as well as for each spot performed, the tool and arm used, the machine settings (power and
pressure). It also contains the following possible error messages that may have occurred during its recording: I LOW, P LOW, PB CAPS.
The ID is entered using the 4 keys +, -
without deleting the previous ones.
The
button is used to retrieve a previously saved report and read it back on the screen.
The current recording must be stopped by pressing the
report view mode.
To delete the contents of a report, you must
display it on the screen using the button
IMS SPOT 14500 TRAFO PRO
A spot count tool keeps count of the different spot weld done using the same cap. If there is no
problem during the welding, the following message is displayed.
The count is displayed at the top left corner of the screen. Press the button
reset the count after changing the caps.
The machine counts the number of points achieved with each arm independently. A warning
message appears on the screen when the limit of the points made by the headings is reached. The
message remains displayed after each point until the counter is reset.
and
buttons.
Saving a report allows you to retrieve the data of a series of spot made with using the clamp, and to
save them on the memory card so that they can be retrieved from a PC for example. JBDC provides
a software called SPOT to read the SD card and edit the logs on a PC. This SPOT software is stored
on the SD card as well as the user manual.
By default, this feature is disabled when the machine is switched on. Pressing the recording button
(on/off) and the «mode» button starts recording the report in the selected log. Pressing the record
button again (on/off) stops the current recording.
or
. When entering an identifier already in use, the machine will record the new points in succession,
button before it can be displayed on the screen. The
Then press the
The following message appears on the
.
screen.
If the input pressure is insufficient to deliver the tightening requested,
the machine beeps and displays, before the weld, the error message
«Insufficient air pressure».
Pressing the trigger a second time is used to «force» the spot weld
using the available pressure. If the tightening recorded is insufficient,
the machine displays «Low pressure».
«p low» is also recorded in the active report.
button.
When the triangle is displayed, a second press
on the
report displayed.
The triangle disappears from the screen auto-
matically after 3 seconds.
EN
for 2 seconds to
and
button is used to exit the
button erases the content of the
.
41

Werbung

loading