Herunterladen Diese Seite drucken

ims PRO SPOT 14500 TRAFO PRO Bedienungsanleitung Seite 40

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Press the
button for 2 seconds to get back to the NORMAL mode.
ERROR MANAGEMENT
Low battery
Invalid tool
Invalid arm
Current too low
40
IMS SPOT 14500 TRAFO PRO
In normal mode, the gun will be limited to 1.5mm thick sheets.
Using the gun, the operator can choose between different tools (mono point, star, impact, heat, dowel pin,
rivet, nut, toothed wheel). Select the desired tool using the + and - keys.
In Manual mode, the maximum possible intensity is 8 kA for a maximum duration of 500 ms. The settings
showing on the screen will not exceed these values.
Set the generator by indicating the thickness of the sheet/panel to weld using + and - keys. It is possible to
adjust the current and time settings when in manual mode.
Various elements may produce errors. They can be split into 4 categories :
1/ Warning messages designed to warn the operator of overheating, lack of pressure or power, etc.
These messages are displayed on the screen and remain visible until a button is pressed.
2/ The faults that occur in relation to insufficient air pressure or power supply.
3/ The serious faults that block the machine. In this case, contact the service department
4/ The thermal protection is linked by a thermistance on the diode bridge and when it activates the
machine is locked and the message «overheating» is displayed.
The message «Battery low» is displayed when the machine is switched on and it indicates that the
battery on the command board is low. This battery is used to record the date and time when the
machine is switched off.
The message «Invalid tool» is displayed when the machine is switched on and indicates that a button
is pushed in, the trigger is pushed in or a permanent short-circuit. Check the trigger or the buttons on
the clamps to remove the message.
The arm used is not compatible with the welding mode selected.
1/ Check the weld
If the current obtained during a spot weld is lower than the expected value (6%), the machine dis-
plays the warning message «Low current, check the weld».
2/ Check the sheets
If the machine cannot deliver the current required, the error message «Low current, check the
sheets» is displayed. The weld does not happen and the fault must be skipped for the weld to happen.
EN

Werbung

loading