Endress+Hauser iTEMP HART TMT 142 Bedienungsanleitung Seite 71

Vorschau ausblenden Andere Handbücher für iTEMP HART TMT 142:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TMT142
Endress+Hauser
No.
Description
15
Read primary variable output information
16
Read final assembly number
17
Write message
18
Write tag, descriptor, date
19
Write final assembly number
Common practice
34
Write primary variable damping value
35
Write primary variable range values
38
Reset configuration changed flag
40
Enter/exit fixed primary variable current mode
42
Perform master reset
44
Write primary variable units
48
Read additional device status
59
Write number of response preambles
E+H specific
144
Read matrix parameter
145
Write matrix parameter
®
• HART
command No. 09 (HART-Cmd #9)
Apart from the analog output, the device makes other measured values available digitally. These
values (PV, SV, TV, QV), including their unit and status, are read out digitally by means of the
HART-Cmd #9 (Read Device Variables with Status).
Description
Measured value
PV
Primary variable
SV
Secondary variable
TV
Tertiary variable
®
• HART
command No. 48 (HART-Cmd #48)
Apart from the response code and the device status byte, the field transmitter calls up a detailed
diagnosis by means of Cmd #48. This diagnosis is 8 bytes long.
Access
r
r
w
w
w
w
w
w
w
w
w
r
w
r
w
Meaning
Corresponds to the configured analog output value
Internal comparison measurement point (unit of the analog output
or °C)
Value from sensor
Commissioning
71