Installation
General guidelines
See Figure 2 below.
To install the detectors correctly, certain rules must be followed.
Do not place the detector on an unstable support (such as a mesh or a poorly
fixed post). See item 1.
Do not position the module facing direct sunlight (item 2).
Make sure that no vegetation interrupt the cells (item 3).
Figure 2: Potential causes of instability
Detector mounting
To attach the detectors to a metallic support, drill 4 holes measuring 3 mm and
use the sheet metal screws provided.
To fix the detectors to a wall, use appropriate screws and wall plugs for the type
of wall (we recommend at least Ø5 x 30 screws).
Drill 4 holes and insert wall plugs.
Position the holes in the adjustable support over the wall plugs.
Note:
Rotate the module to be able to reach the screw holes in the adjustable
support (see Figure 3 on page 8).
SB Series AIR Beam Detectors Installation Manual