Aligning the cells visually
Figure 12: Visual alignment
(1) Viewfinder
(2) Viewfinder image
To align the detector:
1. Slightly unscrew the module's adjustable support.
2. Position your eye at an oblique angle about 5 cm from the module as shown
in Figure 12, item 3.
3. Look in the mirror inside the module to see the image (item 2) of the module
opposite through the viewfinder (item 1) in the side of the cell.
- Horizontal alignment: Rotate the adjustable support by up to 90°.
- Vertical alignment: Turn the thumbscrew (item 4) by up to 10°.
Once the optimal alignment has been achieved, tighten the screw of the
adjustable support to lock horizontal rotation.
Optimization of the detector alignment (without module synchronization)
Figure 13: Optimization of the detector alignment
1. Power cycle the unit (module)
- The buzzer beeps 1 time for SB250-N and SB450-N.
- The buzzer beeps 2 times for the SB2100-N and SB4100-N.
- The buzzer beeps 3 times for the SB4200-N.
16
(3) Oblique angle
(4) Vertical adjustment thumbscrew
SB Series AIR Beam Detectors Installation Manual