When retightening the stuffing box with the pump shaft rotating, tight-fitting working clothes must be
worn without fail. All rotating drive parts must be protected against any contact (e.g. by means of pro­
tective hoods).
Observe the position and diameter of the inlets and outlets according to the pump drawing (see sec­
tion 2.1).
Adjust external control, external converter or manual control unit of the internal converter in a way that
the pump drive does not start-up automatically when activating the device,
The pump is lubricated by the medium pumped. Due to the potential damage to the pump and poten­
tial ignition hazard of the pumped medium due to overheating, dry runs must absolutely be avoided.
An excessive tightening torque may damage the pump (max. allowed tightening torque specified in
pump data sheet, see information in Chapter 7).
The pump may be protected against excessive torques by e.g. installing an overload coupling.
The compatibility of the pumped, heating and sealing media with the shaft sealings (if provided) and
the pump materials must be ensured.
Contact the Barmag Pump Service in cases of doubt.
2.
Machine Layout / Designations
2.1
Machine layout
See dimensional diagrams of the pump and pump set (if included in the scope of delivery of Barmag).
These can be ordered from Barmag if not delivered together with the equipment.
2.2
Designations
Engraved characteristics:
Number of pump
Flow rate
"Barmag"
Item number
Page
16
Customer:
Order:
Edition: