Safety Instructions
The safety instructions are intended for anyone involved with the pump within the scope of installation,
commissioning, operating, and maintenance activities.
Carefully read the guidelines instructions formulated by your company and observe the following safety
instructions and clarifications:
Use the required personal protective devices
(such as safety glasses, safety gloves, and safety clothes).
Do not allow unauthorized persons access to the installation / machine.
The safety data sheets of pumping media and other chemical substances are to be observed!
Be careful when handling the pump because of
- high temperatures
- hot discharging media, sealing media, and gases
- rotating parts
Wear suitable working and protective clothes!
Works on adhesive / drum pumps are only to be carried out with appropriate clothing as protection
from high temperature and possible exposure to hot discharging media, sealing media, and gases.
Rotating drive parts must be enclosed by a cover which cannot be penetrated by splinters.
Do not remove any protective covers of driving parts or other components.
Before beginning repair and service work on the adhesive / drum pump, the pump drive must be elec­
trically switched off and allowed to run down to standstill.
Observe switch‐off regulations!
Secure the switched off drive against unauthorized restart.
1.8
Safety Instructions for Electrically Heated Adhesive Pumps / Drum Pumps or
Clamping Plates
D
Danger!
All adhesive pumps / drum pumps must be earthed. For this purpose, one of the pump fastening
screws may be used.
Protect the electrical heating against short circuit using an appropriate fuse.
Connect the electrical heating to power in installed condition only.
Do not operate the electrical heating without temperature sensor and control.
The heating control must ensure that the max. permissible temperature as specified in the pump data
sheet cannot be exceeded.
The temperature sensor includes two PT100 resistors: One must be used for the heating control, the
other PT100 resistor must be connected to an independent additional temperature monitor. If the max.
permissible temperature as per pump data sheet is exceeded, the electrical heating must be switched
off.
Prevent liquids from flowing over the connecting cable of the electrical heating. Lay the cable taking
this condition into consideration.
Regularly check the connection points of the pumped / sealing medium for leakage.
Do not crush or bend the cable.
The pump may only be operated with personal protection insulation under temperature.