4. Scope of delivery
PegaSys DoorHandle 4.1 with self-locking panic lock
The PegaSys DoorHandle 4.1 only offers full function-
ality with a self-locking panic lock.
1. Combine the PegaSys DoorHandle 4.1 with a self-
locking panic lock.
2. Pay attention to the declarations of conformity of
the lock manufacturers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad
excludes authorisation security class D according to
DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to ma-
nipulate the lock.
1. Seal any escutcheon holes with a blind cylinder, for
example.
2. In the case of FH versions, you must be install a
brass dummy cylinder or locking cylinder.
4. Scope of delivery
PegaSys DoorHandle 4.1 (metal frame version)
Special tool
Quick guide
For FH version:
Blank cylinder
5. Design
1
6. Prepare door (drilling tem-
plate)
PH2 screwdriver at hand.
ü
Pin or scriber at hand.
ü
ü
Drill at hand.
ü
Suitable drill bit at hand (Ø 7.2 mm).
ü
Countersink at hand.
1. Insert the spindle into the mortise lock.
2
2. Place the drilling template on the spindle.
3
3. Align the drill template vertically using the printed
scale.
4. Mark the points to be drilled on the door.
4
46 / 68
PegaSys Door Handle 4.1 Metal frame
5. Remove the drilling template.
5
6. Remove the spindle.
6
7. Remove the mortise lock (PH2).
7
8. Drill the required holes.
8
9. Countersink the holes with the countersink so that
the blind rivet nuts can be pressed into a flush posi-
tion later.
9
10. Fit the mortise lock (PH2).
10
7. For door thickness X: prepare
spindle
Saw at hand.
ü
Vernier calliper at hand.
ü
PH2 screwdriver at hand.
ü
1. For X: measure the door thickness.
2. For X: mark the sawing point on the spindle.
NOTE
9 mm spindle with 8 mm end
The 9 mm spindle has an 8 mm end. This end is inser-
ted into the electronic fitting.
Trim the 9 mm spindle, ensuring that the 8 mm end
is not the cut part.
11
3. For X: trim the spindle with a suitable saw.
12
8. Programming the fitting
13
9. Installing the fitting
ü
Door pre-drilled.
ü
PH2 screwdriver at hand.
TX15 screwdriver at hand.