Fault
Neither the light nor the
motor works
Oil is leaking.
Vibrations
The suction power is
insufficient
The device is hanging
crookedly
Possible Cause
In addition to the above options, check the
following:
The light is defective.
The mains cable is loose.
The valve and the
air inlet opening are
leaking.
Leak at the connection
between the U-profile
and the cover.
A defective rotor blade
can cause vibrations.
The motor is not secured
correctly.
The extractor hood is not
secured correctly.
The distance between
the hob and the
extractor hood is too
great
Too much air circulation
through open windows
and doors.
The mounting screws
are not tightened.
The suspension screws
are not tightened
enough.
Solution
Replace the light.
Connect the wires
according to the circuit
diagram.
Remove the valve and
seal it with glue.
Remove the U-profile
and seal it with soap or
paint.
Replace the rotor blade.
Fasten the motor
securely.
Fasten the extractor
hood securely.
Reduce distance.
Move the device to
another location or close
doors/windows.
Tighten the mounting
screws and align the
device horizontally.
Tighten the suspension
screws and align the
device horizontally.