EMERGENCY OPEN FUNCTION
The emergency open function enables manual unlocking of the CLEAR PRO CONEL retrofit leakage
protection MultiControl 3/4" - 1 1/4", e.g. in the event of a lack of power supply due to a power
failure or due to missing or empty batteries.
/
for the emergency open function, the shut-off handle removed during assembly of the
MultiControl (see chapter 6.3) is required as a tool
/
access to the emergency open function is located under the MultiControl
Fig. 10.1:
/
disconnect all plugs and remove USB-C cable [a], if necessary also LAN cable [b],
/
remove cover [c],
/
pull out the clip [d] and pull up / remove the MultiControl [e] in the direction of the arrow,
/
loosen or pull out the connector housing of the cable harness [f] (see chapter 6.4 „Mounting
MultiControl" / Fig. 6.6)
[c]
[a]
[b]
Fig. 10.2:
/
insert the shut-off handle [g] into the
holder [h]: Move vertically in the
direction of the arrow as far as the
stop
[e]
[d]
[f]
Fig. 10.1
[g]
[h]
Fig. 10.2