9.9 SETTING RANGE
The following table explains the most important terms of the CLEAR PRO CONEL retrofit leakage
protection MultiControl 3/4" - 1 1/4" setting area in the CLEAR PRO APP.
Examples are listed for better understanding.
Explanations and setting options
The individual setting of the CLEAR PRO CONEL retrofit leakage protection
MultiControl 3/4" - 1 1/4", adapted to the user.
Maximum possible number of user profiles: 8
Example:
On weekends, the two children usually come to visit. They both like to take long
and extensive showers. To ensure that the parents also have enough water avai-
lable, create a new profile with the corresponding parameters.
CONEL tip:
Use the intelligent self-learning phase of the CLEAR PRO CONEL retrofit
leakage protection MultiControl 3/4" - 1 1/4" to determine the optimum safety
levels for your new profile.
Maximum possible amount of water tapped in one cycle after opening a tap.
The volume leakage setting ranges from 10 to 9,000 l; And switching off is also
possible.
Example:
The tap with the largest withdrawal quantity is a bathtub with a capacity of
approx. 120 l. Set the presence leakage value to 200 l so that you can fill the
bathtub without any problems and continue to withdraw water.
If a withdrawal is detected that takes longer than the set time at a defined volu-
me, the unit shuts off. The time leakage can be set in half-hourly intervals from
0.5 to 25 hours; Switching off is also possible.
Example:
In addition to the set water quantity for volume leakage, a time period can
be defined during which water may be withdrawn without interruption. If, for
example, the time leakage is set to 60 minutes, the CLEAR PRO CONEL retrofit
leakage protection MultiControl 3/4" - 1 1/4" shuts off after this time has been
exceeded, although the set volume has not yet been reached.