6.2.2 MOUNTING THE LEAKAGE PROTECTION MODULE BETWEEN
WATER SOFTENER AND FILTER
Fig. 6.2.2
/
Securely fasten the adjustable wall support [h] to the wall with the enclosed material (2 dowels,
hanger bolts, washers and hexagon nuts) for stabilisation.
(Fig. 6.2.2 / Fig. 6.2.3 - the CLEAR PRO SOFT is shown here) and set the distance:
/
Dimension A: Water softener CLEAR PRO SOFT:
Dimension A: Water softener CLEAR PRO SOFT TWIN
/
with CLEAR PRO SOFT TWIN, the contact surface of the wall support [a] is positioned on the
two nozzles for the sampling valves
[c]
Fig. 6.2.4:
/
After removing the filter [g], bring the retrofit leakage protection [b] up to the flange of the water
softener [a] and align with the two flat gaskets [e]/[f] (please replace),
/
Tighten the hexagon socket screws M6x130 [d], using the hexagon pin spanner [c] included in the
scope of delivery, alternately crosswise in the direction of the arrow, thus connecting all
components together and checking that the two flange gaskets [e]/[f] are seated correctly.
[d]
[a]
[h]
[a]
[f]
Fig. 6.2.3
min. 50 mm / max. 100 mm
min. 35 mm / max. 85 mm
[b]
[e]
[g]
Fig. 6.2.4