ENGLISH
NOTE: The equipment is provided
with a cable for the connection to the switch
disconnector. If the cable needs to be re-
placed, follow the instructions below.
WARNING: The connection must be
made by authorised, skilled personnel, in
accordance with the applicable legal re-
quirements, using appropriate and speci-
fi ed materials. The appliance is supplied
with 230V/1N 50Hz operating voltage, or
220V/1N 60Hz upon request.
HAZARD: Before doing any work, turn
off the general power supply.
Connect the appliance to the mains power sup-
ply as follows:
If not already in place, install a switch-discon-
)
nector (A) close to the appliance with thermal
magnetic circuit breaker and residual-current
circuit breaker.
Open the hatch (B).
)
Undo the screws (C) and remove the lid (B).
)
Connect the switch-connector (A) to the ter-
)
minal board (E) of the appliance as shown in
the fi gure and in the wiring diagram at the
end of the manual.
WARNING: The connection must be
made in compliance with the relevant appli-
cable legal requirements, and using appro-
priate and recommended materials.
Place the appliance under-
)
neath the hood (A) (see
fi gure).
WARNING:
The gas supply to applianc-
es must be linked to forced-
air ventilation systems.
12
ELECTRICAL CONNECTION
CONNECTION OF FUME EXHAUST VENT
A
HANDLING AND INSTALLATION
B
A
Use a fl exible cable with at least type H07RN-
F characteristics and operating temperature
of at least 80°C.
WARNING: When connecting the ap-
pliance, pay attention to the connection of
the neutral and earth wires; if they are not
connected correctly, the burner does not
switch on.
Put the lid (D) back in place and fi x it using the
)
screws (C) once the operation is complete.
Close the hatch (B).
)
Connection to a fan extractor hood
To carry out this operation, proceed as follows.
A
D
C
E