Herunterladen Diese Seite drucken

Hitachi HRNME Serie Installations- Und Betriebshandbuch Seite 19

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 73
Cancelling the timer
In the normal mode, hold down the (
NEXT SCHEDULE indicator blinks. (Cancellation of all the timer)
While the timer is in cancellation mode, hold down the (
3 seconds. NEXT SCHEDULE is indicated. (Timer activation)
Setting the temperature shifts (energy saving mode)
1. Set the ON/OFF operation as in steps 1 and 2 of the "Setting the timer" section, and then select "S" as
the schedule number.
2. Set the ON/OFF operation in steps 4,5 and 6 of the "Setting the timer" section, and set the ON/OFF
time. The temperature setting is then indicated.
3. Select the temperature shift with the
pressed at this time, the temperature shift is not set and the indication "- -" appears. When the TIMER
switch is pressed, the temperature is indicated and the mode changes to schedule number selection.
4. When the TIMER switch is pressed, the SET and SCHEDULE indicators go out and the mode returns to
normal.
NOTE:
1. When this operation is performed, the temperature shift indicator changes.
2. When this operation is performed, the temperature setting of the CSNET NET WEB or PSC-A64S has a normal range, while the remote
control setting may be changed to a new range.
3. The increase or decrease in the temperature setting during the scheduled time (±3 ºC or ±5 ºC) varies according to the operation mode.
- If the system is operating in FAN, COOL or DRY mode, the temperature variation is + .
- If the system is operating in HEAT, mode, the temperature variation is - .
Automatic operation with heating (anti-freeze protection)
1. In normal mode, hold down the switch for more than 3 seconds to change the operation mode. The
automatic heating setting is activated and the ON indicator appears to the right of the current time. The ON
indication blinks during the automatic heating operation.
Cancellation
While the system is operating in the automatic heating mode, hold down the MODE switch for more than 3
seconds to change back to normal mode.
The automatic heating setting is deactivated, and the ON indication to the right of the current time goes
out.
NOTE:
If the temperature in the room is lower than a predefined value1*, the heating will start up automatically. When the room temperature reaches
the set temperature, the operation stops.
*1 The temperatures 5,10,or 15ºC can be selected using an optional setting.
Operation locking method
To prevent incorrect use of the switches, the switch operation * can be locked.
1. In normal mode, hold down the SELECT  switch for more than 3 seconds. The operation lock is
activated and the OPER.LOCK indication appears. If a switch is pressed while it is locked, the indication
OPER. LOCK blinks.
Cancellation
While the locking operation is activated, hold down the  switch and SELECT simultaneously for more
than 3 seconds to return to normal mode. The locking operation will be cancelled and the OPER. LOCK
indication goes out.
NOTE:
*The switch to be locked can be selected from "operation mode change", "temperature setting", "airflow" and "autolouver" by an optional setting
(F8~Fb) of up to 4 items.
The setting can be changed from CSNET or the sub-remote controller.
PMML0197_r0_04-10.indb 19
INSTALLATION AND OPERATION MANUAL

) DAY / SCHEDULE switches for more than 3 seconds. The

) DAY / SCHEDULE switches for more than

switches. "3" or "5" can be selected. If the reset switch is
19
1234S
Mon
:
NEXT SCHEDULE
:
ON
Mon
1234S
:
NEXT SCHEDULE
:
ON
SET
1234S
:
SCHEDULE
:
ON
4
OFF
1234S
SET
:
SCHEDULE
:
ON
4
OFF
1234S
SET
:
SCHEDULE
:
ON
4
OFF
Mon
S
:
NEXT SCHEDULE
:
OFF
Mon
:
NEXT SCHEDULE
:
ON
OFF
Mon
:
NEXT SCHEDULE
:
OFF
Mon
:
NEXT SCHEDULE
:
OFF
OPER.LOCK
Mon
:
NEXT SCHEDULE
:
OFF
08/07/2010 9:20:21

Werbung

loading