All manuals and user guides at all-guides.com
Sensitivity
The Nivector is factory-set so that it can be used for most
applications without any further adjustment. The
electronic switchpoint of the Nivector is set for materials
with a grain size ø < 10 mm and a dielectric constant
ε
≥ 1.6. assuming that the Protector mounting adapter is
r
being used with it.
W W i i t t h h o o u u t t t th h e e P P r r o o t t e e c c t t o o r r for materials with ε
a recalibration must be carried out by the user:
• Disconnect the power supply to the Nivector
• Dismantle the Nivector and remove the connecting cap
• Place the Nivector 6 mm from an electrically conductive
and grounded surface (vessel, metal sheet)
Fig. 10
When adjusting the
sensitivity, the
connecting terminals
must be connected to
a voltage supply!
Observe safety
regulations!
Adjustment to be
carried out by trained
personnel only!
• Reconnect the Nivector to the power supply
• The MIN-MAX switch on the Nivector must be in the MIN
D D e e c c r r ea
eas s i i n n g g t t h h e e
S S w w i i t t c c h h i i n n g g
position and the LED must be lit. If the LED is not lit,
D D i i s s t t a a n n c c e e
then turn the sensitivity potentiometer counterclockwise
until the LED lights up (see Fig. A A )
This decreases the sensitivity and means that the
switching distance at the tip of the Nivectors is reduced.
To act as the electrical switchpoint, the material must be
within this switching distance (see also Fig. 10).
• Slowly turn the potentiometer clockwise until the LED is
I I n n c c r r ea
eas s i i n n g g t t h h e e
S S w w i i t t c c h h i i n n g g
no longer lit (see Fig. B B )
D D i i s s t t a a n n c c e e
This increases the switching distance.
• Turn back the potentiometer 3/4 of a turn
counterclockwise (see Fig. C C )
Fig. 11
Proceed as indicated
in the sequence
shown.