① After the battery module is placed in the control box, take out a 140 mm communication
cable to connect the communication port of the battery module and the high-voltage control box,
and 11x110mm communication cables to connect the battery module communication port
(IN-OUT) from top to bottom. (12 communication cables in total).
★ The communication port (OUT) of the battery module at the bottom is not connected to the
communication cable. Instead, this port is sealed with a 120ohm terminal resistor.
② Take out a 220 mm positive power cord and connect the positive pole of the battery module
at the top to the positive pole of the high-voltage control box. Take out 11x200mm battery
module power cords and connect the power ports (B- to B+) in a top to bottom order to form a
series circuit. For aesthetics, connect the negative power pole of the first battery module to the
negative power pole of the high-voltage control box from the bottom of the battery module to
the back of the rack. On the back of the rack, a plane-head-shaped tie is used to secure the cable
harness. (12 power cords in total)
③ Take out the external positive power cord EPCable5.0 and external negative power cord
ENCable5.0, and plug them into PCS interfaces, respectively.