4. Programmable Functions
4.1 Model Settings
4.2 Step Settings
With each program (=model) the machine settings described in the
following are also stored. The model settings must be set before
starting the programming mode.
Along with a model the following base machine settings are stored:
–
Model-CRC(checksum)
–
Base stitch length (3, 4, 5, 6 mm) (see Chapter 6.1.5)
–
Stretch value (0-5) (see Chapter 6.1.2)
–
Crimping value as of which a higher thread tension is switched on
(0-15) (see Chapter 6.1.6)
–
Stitch condensation generally turned on / off (see Chapter 6.1.4)
–
Tape advance turned on / off (see Chapter 6.1.3)
–
Tape advance mechanics existing / switched off
(see Chapter 6.1.16)
–
Number of steps in the model
–
Model number
In each step the following settings are stored :
–
Crimping value (0-15) incl. 1/2 values
–
Additional tape tensioner on / off
–
0H - distance with / without tape
–
High lift on / off
–
Stitch condensation on / off
–
Part end marking