3
Description
3.1 Construction
The inverter consists of the following components:
1 Rotary switch for switching on/off and setting the switch-on threshold (see
chapter 5.2).
2 LED for indicating the operating modes
3 Battery cable: red = +, approx. 1.5 m long
4 Battery cable: black = –, approx. 1.5 m long
5 Mains cable: 3-core, approx. 1.5 m long Battery cable: black = –, approx.
1.5 m long
6 RJ45 connection, only for communication with PA Link1, see the PA Link1
operating instructions
3.2 LED statuses
LED col-
Status
our
Dark
Permanently illuminated Consumer device switched on
Green
Blinking slowly
Blinking slowly
Red
Blinking quickly
Permanently illuminated Overheating
Blinking slowly
Red-
green
Blinking quickly
Explanation:
Blinking slowly (1 second):
Blinking quickly (0.1 second):
3.3 Rotary switch settings
Setting
Sensitivity
Off
Standby
Low sensitivity
left
Standby
Medium sensitivity Power supply starts reacting at medium loads
centre
Standby
High sensitivity
right
On
All On
754.923 | Z01 | 15.29
Meaning
Power supply switched off
Standby operation, no consumer device
was recognized
System error. Inform your installation com-
pany and have them check the system
Overcurrent
Battery undervoltage or low charge state
Battery overvoltage
Load detection
Power supply switched off
Power supply only starts reacting at heavy loads
Power supply starts reacting at small loads
Power supply always switched on
Setting for parallel operation, see the separate
PA Link1 operating instructions, in individual
operation the same as setting "On"