Wiring details
8. Wiring
8.1. Power supply
The ECoSBoost gets its power via a 2.1mm DC-socket. The secon-
dary (supply) voltage corresponds with the track voltage; voltage
stabilising or adjustment does not take place. The ECoSBoost has
its own internal protective circuitry for under-voltage and overload
(-current).
• Only use the power supply provided for ECoSBoost. Other
transformers may lead to reduced output or in extreme cases
to damage of the command station. We will not accept any
warranty claims arising from the use of a different power sup-
ply!
• Please use the power supply provided with ECoSBoost solely
for powering ECoSBoost. Do not use it for other household
appliances.
• Check the power supply regularly for any visible damage of
the housing or the mains cable. Damaged parts may never be
used! Do not attempt to repair the power supply! Extreme
danger – risk of fatal injury!
• Make sure there is sufficient ventilation around the power sup-
ply. Mounting in furniture without air circulation may lead to
overheating of even fire!
A power supply with the following characteristics is delivered with
the ECoSBoost:
8.2.1. 5A Power supply
VIn:
VOut:
Output current:
Plug:
8.1.1. Setting the output voltage
The power pack generates a stabilised voltage that serves to pow-
er your model train layout. The output voltage must be adjusted to
the appropriate value subject to the scale of your trains.
For this purpose there is a small, round opening at the front of
the power pack that allows you to set the voltage with the aid of
a screw driver:
Left hand limit:
Right hand limit:
In figure three you can find some common settings.
8.1.2. Practical voltage settings
We recommend the following settings for the different scales:
• N gauge:
• H0 DC (DCC):
• H0 three-rail-system: 18V - 20V
• 1 gauge:
• G gauge:
6
100V – 240 V AC, 50 / 60 Hz
Adjustable from 15V - 21V DC, stabilised
8A max.
DC plug, 2.1mm, 1.8m wire harness
approx. 14.5V
approx. 21.5V
15V - 16V
16V - 18V
18V - 21V
20V - 21V
14V
Figure 3
8.1.3. Connections
• First of all connect the power supply cable with the corresponding
socket of the power supply. Then plug the cable in an appropriate
power socket.
Figure 4 shows how to the power supply can be connected to the
ECoSBoostBoost.
ECoSBoost 7A 50012
Figure 4
Never use Y adapters for connecting the power supply to other
devices of your model railway layout besides the ECoSBoostBoost!
This could cause an inadmissible contact to ground that could lead
to the destruction of your ECoSBoostBoost!
21V
15V
N Scale
18V
H0 Scale
21V
G Scale

Werbung