NOTICE!
A
 Only use the device as intended.
 The roof air conditioner is not suitable for use in agricultural or
construction vehicles.
 Do not make any alterations or conversions to the device.
 Never drive through automatic car washes when the roof air
conditioner is mounted.
 If faults occur in thes refrigerant circuit, the system must be
checked by a specialist company and repaired properly. The
refrigerant must never be released into the air.
NOTE
I
 Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height
entered in the vehicle documents needs to be altered:
– FreshJet 1100, 1700, 2200: increased height 225 mm
– FreshJet 2600, 3200: increased height 248 mm
2.2

Handling electrical cables

WARNING!
!
 The electrical power supply may only be connected by a
qualified electrician (e.g. VDE 0100, Part 721 in Germany).
CAUTION!
!
 Fit a fuse of at least 10 amps to the connection with the vehicle's
power supply.
 Attach and lay the cables so that they cannot be tripped over or
damaged.
NOTICE!
A
 Use cable ducts to lay cables through walls with sharp edges.
 Do not lay loose or bent cables next to electrically conductive
materials (metal).
 Do not pull on the cables.
EN
Safety and installation instructions
29