4. Precautions & Recommendations
4.1 Transportation and Storage
During transportation, the machine should be carefully handled and do not put it upside down to prevent from
damaging to the shell and inside. The packaged machine should be stored in a ventilated warehouse without
corrosive gas. If it needs to be stored in open air temporarily, measurement against raining is needed.
4.2 Notices for Installment
Installation:
1. Before using, make sure the installation and operation are correct and conform to the requirements of
electric, health and safety.
2. Before Connection to Power Supply:
Remove all packaging. Check the oven and parts for damage. Report any damage immediately to the
carrier or supplier.
Remove any protective plastic coating from the outer panels.
Check the following parts have been supplied with your oven:
4 x Oven shelves. If there's any one missing, please contact your dealer ASAP.
Mount the legs and the handle.
3. Location:
To ensure correct ventilation for the motor, the following minimum installation clearances are to be
adhered to: Top 200mm, Rear 25mm, Left-hand side 25mm, Right-hand side 25mm.
Position the oven in its working position. Use a spirit level to ensure oven is level from side to side and
front to back. (If this is not carried out, uneven cooking could occur).
The unit should be positioned such that the oven shelves are easily reachable for loading and unloading.
THE VENT LOCATED ON THE OVEN TOP MUST NEVER BE OBSTRUCTED.
4. Double Unit
When it is desired to mount one unit on top of another the 31mm high spacer feet must be used. These
short feet should be screwed on, and the unit lifted on top of the bottom unit, where it locates safely
under its own weight, for normal applications.
5. Electrical Connection
Ensure unit is fitted with appropriate cord and plug.
Remove the back panel, connect the terminal block and grounding lug.
THIS APPLIANCE MUST BE GROUNDED
6. Water conduit Connection (applicable for model YXD-6A-P only).
Notice:
1. The supply voltage should comply with the working voltage of the appliance.
2. The appliance is equipped with an earth bolt at its back, which should be connected with copper wire no
less than 1.5mm² and earth wire that conforming to safety regulations reliably.
3. After installation, check that whether the connection is loose, whether the voltage is normal and whether
the safety grounding is reliable.
4. The fixed arrangement of wire should be equipped with an all-pole disconnecting switch with a contact
opening of 3mm on its poles. It is advisable to install a grounding leakage protection switch. Do not pile up
sundries in front of the switch, for convenient operation sake.
5. Vicinity of the mounting position should not store flammable or explosive objects. The ambient temperature
should be lower than 45°C and the relative humidity should be below 85%.
6. Installation should be done by professional technician.
www.combisteel.com