Indication sounds:
A double sound is emitted every
90 seconds (short beep).
90 second
Volume:
Cause: Contamination of the device
Silencing the
indication sounds:
24 h
All indication sounds can be tempo-
rarily deactivated by pressing the
Test/Stop button (Fig. 1, IV.)
(battery error message and conta-
mination warning: 24 hours).
Warranty and guarantee are inva-
lidated if the device is damaged!
Do not immerse the
device in water!
Battery cannot
be replaced (see
"General Safety
Information")
Closed system; only the cover
can be changed
Switching the device off:
Pull out the red activation
button to switch the
device off.
– 24 –
CHOOSING A LOCATION (acc. DIN 14676)
Fig. 2
RM
RM
Bedroom
RM
Children's room
RM
Living room
RM
RM
RM
Kitchen
RM
Boiler /
utility room
RM
RM
RM
Workshop
RM
RM
Bedroom
Bath
Kitchen
RM
RM
RM
RM
Childrens
Childrens
Living room
room
room
RM at least
optimal
RM
- Do not install in environments that are subject to drafts
(e.g. fan, ventilation...) or bathrooms
- Unit is suitable for kitchens, if false alarms due to
steam can be ruled out
- At the highest installation position on the ceiling in the
middle of the room (not on walls )
- Minimum distance of 50 cm from walls, furniture,
lamps
- Monitored area maximum 60 m
2
with maximum ceiling
height of 6 m
- Distance between two devices maximum 15 m
- Corridor length maximum 7.5 m
- Not onto the ceiling beam for ceiling beams with a
height of >20 cm, but 1 device per intermediate space
up to a maximum of 36 m
in surface area
2
- For ceiling beams with a height of <20 cm, a detector
at the centre of the room (also possible on ceiling
beam)
- Platforms/galleries <16 m
and at least 2 m long and
2
wide: 1 detector
• over 16 m
2
: install additional detectors
- Roof slopes (slopes below 20° are considered flat
ceilings):
> 20°
> 1.00
1/2
1/2
> 20°
< 1.00
> 20°
In the event of a fire, this device quickly detects the
build-up of smoke and also the associated rise in
temperature in the room. In order to warn you in good
time, it then emits a loud alarm sound. If you decide
that there is no real need to escape the building you
can temporarily deactivate this signal (for approx.
10 minutes), or temporarily disable it before sounding,
by gently pressing the Test/Stop button (Fig. 1, IV). We
recommend that you then provide good ventilation to
the room to prevent the alarm being triggered again.