While pulling the latching lever of the safety latch back, the hand lever can be moved to the
"OFF" position. The unit is demagnetised and can be removed from the load.
Attention: Ensure good contact to the load! Take into account any reduction in load
capacity by air gap, material, material thickness, material shape or reduced contact
surface.
Attention: Ensure good contact to the load. Take into account any reduction in load
capacity by air gap and material.
Attention: For lifting and transporting always comply with the safety instructions in
sections "Correct operation" and "Incorrect operation".
Diagramm: WLL / Luftspalt
Diagram: Adhesive force / Air gap
Diagramme: Force d'adhérence / Entrefer
100 %
75 %
50 %
25 %
0 %
0
ON
OFF
OFF
ON
TPM 3000
TPM 2000
TPM 1000
TPM 800
TPM 500
TPM 300
TPM 100
0,5
1,0
1,5
Luftspalt [mm]
Air gap [mm]
Entrefer [mm]
©
2017 Columbus McKinnon Industrial Products GmbH
ON
OFF
OFF
ON
Diagramm: WLL / Plattendicke
Diagram: Adhesive force / Flat thickness
Diagramme: Force d'adhérence / épaisseur de plaque
85
80
75
TPM 3000
70
TPM 2000
65
TPM 1000
60
TPM 800
55
TPM 500
50
TPM 300
45
TPM 100
40
35
30
25
20
15
10
5
0
100 %
75 %
50 %
Prozent der max. Tragfähigkeit
Percentage of max. capacity
Pourcentage de la charge maximum
17
0 %

Werbung