NTRODUCTION
Products of CMCO Industrial Products GmbH have been built in accordance with the state-of-
the-art and generally accepted engineering standards. Nonetheless, incorrect handling when
using the products may cause dangers to life and limb of the user or third parties and/or
damage to the hoist or other property.
The operating personnel must have been instructed before starting work. For this purpose, all
operators must read these operating instructions carefully prior to the initial operation.
These operating instructions are intended to acquaint the user with the product and enable
him to use it to the full extent of its intended capabilities. The operating instructions contain
important information on how to operate the product in a safe, correct and economic way.
Acting in accordance with these instructions helps to avoid dangers, reduce repair costs and
downtimes and to increase the reliability and lifetime of the product. The instructions must
always be available at the place where the product is operated. Apart from the operating
instructions and the accident prevention act valid for the respective country and area where
the product is used, the commonly accepted regulations for safe and professional work must
also be adhered to.
The personnel responsible for operation, maintenance or repair of the product must read,
understand and follow these operating instructions.
The indicated protective measures will only provide the necessary safety, if the product is
operated correctly and installed and/or maintained according to the instructions. The operating
company is committed to ensure safe and trouble-free operation of the product.
C
O
ORRECT
PERATION
The load lifting attachment is used for lifting, lowering and transporting single horizontal
sheets, flat and round steel and other loads of ferro-magnetic material.
Any different or exceeding use is considered incorrect. Columbus McKinnon Industrial
Products GmbH will not accept any liability for damage resulting from such use. The risk is
borne by the user/operating company alone.
The load capacity indicated on the unit is the maximum working load limit (WLL) that may be
attached.
Do not allow personnel to stay or pass under a suspended load.
A lifted or clamped load must not be left unattended or remain lifted or clamped for a longer
period of time.
The operator may start moving the load only after it has been attached correctly and all
persons are clear of the danger zone.
When suspending the load lifting attachment, the operator must ensure that neither the load
lifting attachment, the suspension (e.g. hook, shackle, etc.) nor the load pose a danger to
himself or other personnel.
Prior to operation of the load lifting attachment in special atmospheres (high humidity, salty,
caustic, alkaline) or handling hazardous goods (e.g. molten compounds, radioactive materials)
consult the manufacturer for advice.
The load lifting attachment may be used at ambient temperatures between –10 °C and +60 °C
and at a max. air humidity of 80%. In this case the temperature of the load must not exceed
+60 °C, since metals lose their magnetic properties at higher temperatures. Consult the
manufacturer in the case of extreme working conditions.
The information about a reduction of the load capacity in, Tab. 1, 2 and on the identity plate
must be taken into account.
©