7.9 - Parameter-setting
console (PX LCD)
The console option provides access to the drive internal
settings (terminal block configuration, ramp, speed and PI
settings, etc).
See VARMECA 30 parameter-setting manual.
Description of the option:
1 PX LCD console, 1 cable L = 3 m
PX LCD parameter-setting console
For adjustment, apply Note 1
7.10 - Parameter-setting software (VMA
SOFT)
This option provides access to the drive internal settings from a
PC. The software is compatible with WINDOWS 7.
See VARMECA 30 parameter-setting manual.
Description of the option:
1 cable L = 1.5 m
The software can be downloaded directly from the Web :
www.leroysomer.com.
For adjustment, apply Note 1 in page 27
7.11 - Operator display (PAD VMA 30)
Presentation of the operator display :
The PADVMA30 operator display consists of a display unit,
three control buttons and three parameter-setting keys.
VARMECA PADVMA30
A
B
E
F
G
For adjustment, apply Note 1
Installation and maintenance - VARMECA 30
3776 en - 2017.10 / n
OPTIONS
Ref.
Display comprising 4 x 7-segment digits for
indicating:
- the drive operating status
A
- certain operating data
- the adjustment parameters (01 to 80)
and their value.
LED providing a sign for the data (the lit LED
B
corresponds to the «-» sign).
Keys which can be used to scroll up and down
through the parameters or their value. These keys
C
can also be used to vary the speed.
Keys which can be used to switch from standard
mode to parameter-setting mode.
D
In parameter-setting mode, the parameter number
and value are displayed alternately on the display.
In keypad mode, these buttons are used for the
E
following commands:
- reverse,
F
- stop, clear fault,
G
- forward.
The parameter setting to use the PAD VMA30 is described in
the Parameter setting document 3847.
7.12 - XPress Key (PX Key)
7.12.1 - General
The XPress Key option is used to save a copy of all the
VARMECA 30 parameters so that they can be duplicated very
simply in another drive.
For adjustment, apply Note 1
7.12.2 - Setting drive parameters with XPress Key
• Connect XPress Key to the serial port via a RJ45 connector.
• With the drive locked, press the «Key» button for a first time.
Confirm the transfer of parameters into the drive by pressing
the «Key» button a second time.
C
CAUTION: If confirmation is not received within
10 seconds, the procedure is cancelled.
D
Note 1
: during the intervention, apply the following
procedure:
1 - Power off the equipment
2 - Wait the appropriate time before opening
3 - Open the cover and connect the option
4 - Refit the cover to ensure the assembly is IP20 (cord
passage or access to the adjustment potentiometer)
5 - Once the adjustments completed, repeat the procedure
to remove the option. Power on only once the cover is
closed. Apply the recommendations in paragraph 4.
Function