Designation
B 31/32 or B 33/34
BMA 31/32 or BMA 33/34
BMAVAR 31/32 or BMAVAR 33/34
CVI VMA 31/32 or CVI VMA 33/34
ESFR VMA 31/32 or ESFR VMA 33/34
RF100 – RF200 – RF600
RF – BRR – 800 – 200
PX LCD
VMA SOFT
PAD VMA 31/32 or PAD VMA 33/34
PX KEY
FLT VMA 31-32M 110/FLT VMA 32M 150
FLT VMA 31/32T 220/FLT VMA 32T 400
FLT VMA 33
FLT VMA 34
1.3 - Characteristics
1.3.1 - Electrical data
Power supply
Phase voltage imbalance
Output voltage
Power range (kW)
Maximum number of
power-ups per hour
*0.37 kW max. for 115 V supply
**7.5 kW max. for 230 V supply
1.3.2 - Characteristics and functions
Characteristics
Motor frequency variation
range
Efficiency
Overload
Installation and maintenance - VARMECA 30
3776 en - 2017.10 / n
GENERAL INFORMATION
OPERATING EXTENSIONS
Integrated speed control knob
Speed control knob and integrated run-stop control knob
Speed control knob and integrated stop forward/reverse control knob
Integrated speed control
Brake control
Braking resistor Power 100, 200 and 600 W
Braking resistor Power 800 W – External mounting
Parameter-setting console
Parameter-setting software
Local display unit
Copy key
EMC filter for residential environment – Filter for the single phase range
EMC filter for residential environment – Filter for the VMA 31/32 three phase range
EMC filter for industrial environment – Mounting for VMA 33 TL/T
EMC filter for industrial environment – Mounting for VMA 34 TL/T
Single-phase supply
110V -10 % to 120V +10 % 50-60Hz ± 2 %
200V -10 % to 240V +10 % 50-60Hz ± 2 %
-
From 0 V to input voltage
0.25 - 0.37* - 0.55 - 0.75 - 0.9 - 1.1 - 1.5
10
- 10 to 80 Hz at constant torque (factory setting can be modified with parameter-setting option)
- 10 to 50 Hz for general applications (factory setting can be modified with parameter-setting option)
- 0 to Fmax depending on thermal and mechanical limits (Fmax = 400 Hz ; LEROY-SOMER to
be consulted anytime the applications requires the drive to run at more than 150 Hz)
97.5% motor efficiency
150% of In for 60 s
10 times per hour
Description
3-phase supply
200V -10 % to 240V +10 % 50-60Hz ± 2 %
380V -10 % to 480V +10 % 50-60Hz ± 2 %
3%
From 0 V to input voltage
0.25 - 0.37 - 0.55 - 0.75 - 0.9 -1.1 - 1.5 - 4 -
5.5 - 7.5** - 9 - 11
100
VARMECA 30