7.5 - IP 20 braking resistor
(RF100 – RF200 – RF600)
For operation in 4 quadrants and energy dissipation, resistors
can be fixed directly onto the VARMECA casing. In this case,
the jumper between terminals FI and R- should be removed
(VMA 31 and 32).
RF 100
P
peak
thermal
kW
3.2
VMA 31T/TL
VMA 31M
0.8
VMA 32T/TL
3.2
VMA 32M
0.8
RF 600
P
peak
thermal
kW
VMA 33/34T/TL
12.8
External resistors with greater thermal power can be used,
provided that the minimum ohmic value of 180 W (RF 100 –
RF 200) or 50 W (RF 600) is respected.
7.6 - IP 20 external braking resistor (RF -
BRR - 800 - 200)
P peak kW
3.2
VMA 31/32T-TL
VMA 31/32M
0.8
26
RF 200
P
P
P
Value
peak
thermal
W
kW
kW
kW
3.2
0.8
0.1
200
0.2
3.2
0.8
P
Value
W
kW
0.6
50 : (2x100 in parallel)
P thermal kW
W value
0.8
OPTIONS
7.7 - Power supply and sequential brake
control (ESFR VMA 31/32)
The brake has a built-in power supply. The brake is controlled
according to a sequence which can be adjusted using the
VARMECA parameters.
7.8 - Power supply and sequential brake
control (ESFR VMA 33/34)
The brake has a built-in power supply. The brake is controlled
according to a sequence which can be adjusted using the
VARMECA parameters. See VARMECA 30 parameter-setting
manual.
Value
W
200
(2x100
in
series)
200
Installation and maintenance - VARMECA 30