Ensure good ventilation. When the sauna
unit has been in use for some time, check
that there is no risk of overheating.
Check that the sauna unit is correctly
earthed and that all the wires are correctly
connected and free from oxide.
REPLACING THE HEATER ELEMENT
1.
Switch off the sauna unit and disconnect
the power supply.
2.
Wait until the sauna unit has cooled and
then remove it from the wall and put it
lying flat on the floor.
3.
Undo the screws and remove the bottom
casing.
4.
Mark all the wires and disconnect them
from the heater element.
5.
Undo the screws and pull out the heater
element from the sauna unit.
6.
Put in the heater element and connect all
the wires in the reverse order.