3.4.
Initialization - phase 2
 Click on PHASE 2, to select programs.
The TS IDs (transport stream IDs), the Network ID and the Network Name can be changed. If you use several MIE in a network,
then the network IDs must be the same and the network name should also be the same. Transport stream IDs, on the other hand,
may only be assigned once in the network.
Different LCN standards can be selected with the drop down menu Region.
3.4.1.
Assigning programmes
Every tuner is assigned to a modulator. The programmes of the tuner can only be assigned to the associated modulator.
 For example, click on M1.
The program is assigned to modulator 1. The button of the modulator is highlighted in colour (a new click on a modulator allow
the assignment to be cancelled. The modulator fades then again).
Chosen
programs for
modulators 1
to 8
 Click on SAVE CHANGES.
The assignment is saved to the device.
Modulator fill level
The modulator fill level is displayed in a status overlay. This status overlay can be moved on the page.
The X button hides the status overlay. The Save button saves configuration changes and then displays the new modulator fill
level.
2023-06-15 | Technical improvements, changes in design, printing- and other errors reserved. | BA_MIE-N.pdf |