4.12. NMS (with MIS 1-11)
A device can monitor up to five other devices and serve as a backup device for these devices. If certain configurable conditions
apply (input error, output error, operating voltage error, etc.), then the backup device is switched to.
Switching is only done if the backup device does not also fail. Switching will not occur, for example, if the IPTV input is missing on
both devices or both are connected to the same failed power source.
4.12.1. Requirements
A valid license (MIS 1-11) must be installed for the backup device (see 3.8 Licenses for Software Extensions on page 53).
All devices must be connected via the control ports (ideally in the same IP subnet)
The backup device should be identical in construction to the monitored devices so that all outputs are redundant. If a device
with fewer outputs is used as a backup device, only the available output channels are replaced in the event of a fault.
4.12.2. Configuring Device Redundancy
Device redundancy is configured on the backup device.
 Click MAINTENANCE > DEVICE REDUNDANCY.
The DEVICE REPLACEMENT dialog opens.