Operation instructions | MIE 8-00N | MIE 16-00N | MIE 32-00N | MIE 4-02N | MIE 8-02N | MIE 3-02N | MIE 6-02N
3.4.8.
OTA upgrade
To enable an Over-the-Air upgrade, two functions are available in the configuration:
Non-referenced PIDs can be manually added to the output modulators
Custom descriptors can be added to the NIT
Both are located in PHASE 2 under ADVANCED OPTIONS.
Note: The function requires a valid license for "PID-Filtering" (see 3.8 on page 53).
Add non-referenced PIDs
Requirement: In PHASE 1 a transport stream must already be selected which contains the unreferenced PID/PIDs.
 Click in PHASE 2 on ADVANCED OPTIONS.
A dialog with options will open.
 Under Add unreferenced PIDs, click the green plus sign in the table header.
A line for entering the PID is inserted.
 Under Input, select one of the available input streams.
 Under In PID, enter an unreferenced PID.
 Select the output Modulator.
 Under Out PID, enter the output PID. The output PID can be the same or different from the input PID.
 Click on the green plus sign next to the line.
The entered data are inserted.
 If necessary, enter additional non-referenced PIDs.
Page 32 of 70
BA_MIE-N.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2023-06-15