Temperature tables

Measuring system Promass 83 (compact version)
at T
= 60 °C
a
Promass A DN 1...4
Promass F
DN 8...150
Promass I
DN 8...50, 15 FB, 25 FB, 40 FB
Promass M DN 8...80
Promass E
DN 8...50
Promass H DN 8...50
The minimum medium temperature is –50 °C for Promass A/F/I/M/H.
The minimum medium temperature is –40 °C for Promass E.
Sensor Promass (remote version)
at T
= 60 °C
a
Promass A DN 1...4
Promass F
DN 8...150
Promass I
DN 8...50, 15 FB, 25 FB, 40 FB
Promass M DN 8...80
Promass E
DN 8...50
Promass H DN 8...50
The minimum medium temperature is –50 °C for Promass A/F/I/M/H.
The minimum medium temperature is –40 °C for Promass E.
Transmitter Promass 83 (remote version)
The Promass 83 transmitter has a T5 temperature class rating for operation at ambient
temperatures up to T
= 60 °C.
a
Note:
At the specified medium temperatures, the equipment is not subjected to temperatures
impermissible for the temperature class in question.
Description of Promass I
DN xx FB = DN xx "Full Bore"
Max. medium temperature [°C] in
T6
T5
T4
95
130
190
95
130
190
95
130
150
95
130
150
95
125
125
95
130
190
Max. medium temperature [°C] in
T6
T5
T4
T3
80
95
130
190
80
95
130
190
80
95
130
150
80
95
130
150
80
95
125
125
80
95
130
190
PROline Promass 83
T3
T2
T1
200
200
200
200
150
150
150
150
125
125
200
200
T2
T1
200
200
200
200
150
150
150
150
125
125
200
200