Installation space

Reserve space required to install the indoor unit
and for service work.
<Installation space>
REQUIREMENT
When using the air conditioner under condition of
high humidity, attach the thermal insulator to the
side face and the rear side of the indoor unit.
The lighting term setup of the filter sign (Notification of filter cleaning) of the remote controller can be changed
according to the condition of installation. If the room is not heated due to the installation place or construction of the
room, the detection temperature of heating can be raised.
For setup method, refer to "Change of lighting term of filter sign" and "To secure better effect of heating" in the
Applicable controls of this Manual.

In case of wireless type

The sensor of indoor unit with wireless remote controller can
receive a signal within approx. 8m. Based upon it, determine
a place where the remote controller is operated and the
installation place of the indoor unit.
• To prevent a malfunction, select a place where is not
influenced by a florescent light or direct sunlight.
• Two or more (Up to 6 units) indoor units with wireless
remote controller can be installed in the same room.
3

INSTALLATION OF INDOOR UNIT

Install the air conditioner certainly to sufficiently withstand the weight.
If the strength is insufficient, the unit may fall down resulting in human injury.
Perform a specified installation work to guard against strong wind or earthquake.
An incomplete installation can cause accidents by the units falling and dropping.
Strictly comply with the following rules to prevent damage of the indoor units and human injury.
At installing the unit, keep the following items.
• Be sure to take measures to prevent falling at the wall surface and the floor and fix it surely considering
prevention of accident of falling because this unit is formed into a thin type. If it is not fixed, a falling accident
may occur.
• After installation of the indoor unit to the specified place, fix it to the wall and the floor immediately for safety.
• Do not put a heavy article on the indoor unit. (Even units are packaged)
(In case of right direction piping)
WARNING
REQUIREMENT
4
500mm or more
Front side
200mm
or more
Front side