DESCALE (dESc)
NOTE
Even if you used the provided water filter‭ , ‬ w e
recommend you to descale if there is scale build-
up in the water tank‭ . ‬
Only descale via the descale menu‭ . ‬
NOTE
Ensure that the water filter is removed from the
water tank before adding the descaling powder
when descaling the machine.
1 – Prepare for Descale
a. Empty the drip tray and insert into position.
b. Turn the machine off and allow to cool for at
least 4 hours. With the machine off, press and
hold the 1 CUP button, then press and hold
the POWER button together for
3 seconds. rSEt will appear on the LCD.
THEN PRESS
& HOLD
c. Rotate SELECT dial until 'dESC" appears on
LCD and press the dial to confirm.
SELECT
SELECT
SELECT
SELECT
|
TEMP
TEXTURE
2 – Empty Boilers
a. Remove the grey silicone cover on the lower
b.
c. Place a cloth over the drip tray to prevent
d.
e. Use a flat head screw driver to rotate the
If there's no water released into the drip tray‭ , ‬ p ress
and hold the 1‭ ‬ C UP button for 3‭ ‬ s econds‭ . ‬ T his will
release water from the boiler‭ . ‬
POWER
When the water is completely empty, close the
valve by rotating screws clock-wise until seated.
Do not overtighten screws to avoid damages
to the valves.
SELECT
SELECT
SELECT
SELECT
|
TEMP
TEXTURE
front panel marked DESCALE ACCESS.
REMOVE
steam escaping.
right valve counter-clockwise SLOWLY
until fully open. As the valve opens, steam
may be released.