supplier.
 All electrical work must be carried out by a qualified professional. Do
not modify the energy supply. The connection must be carried out in
accordance with the current local and legal regulations
1. Turn off the energy supply ( fuse box).
2. Provide an opening meeting the dimensions on the drawing below.
3. Place the hob in the built-in opening.
4. Place the oven near the built-in opening.
5. Connect the oven to the mains.
6. Partially insert the oven into the opening and connect the oven to the hob. The
connectors at the end of the group of wires coming out of the hob should be
inserted into the appropriate sockets of the control panel of the oven according
to their colour, i.e. a black connector should be inserted into a socket marked
with the same colour.
7. Complete the installation of the appliance and fix the oven with 4 screws (fig. 2,
right side).

2.4 Electrical connection

Instructions for the installer (qualified professional)
❖ The cooker is manufactured to work with three-phase alternating current
(400V3N~50Hz). Remember that the connection wire should match the
connection type and the power rating of the cooker. The connection cable must
be secured in a strain-relief clamp. The ground wire must be connected to the
31