MiniVent M1/100/120 F

Performance data

The unit type plate gives an indication of the mandatory electrical values; which must be coordinated with the
local supply network. The fan performances were established on a test stand according to DIN EN ISO 5801.
Noise data that refers to certain distances apply to free field conditions. With regard to installation, the sound
pressure level can differ significantly from the catalogue data, as it is highly dependent on the installation con-
ditions, i.e. on the absorption capability of the room and the room size among other factors.

Personnel qualification

m The electrical connection and commissioning as well as the installation, servicing and maintenance
of the fan must only be carried out by qualified electricians .
MiniVent M1/100/120 F mini fans can be used by children over the age of 8 as well as persons with physical,
sensory, or mental disabilities or lack of experience and knowledge, if they are supervised or instructed with
regard to the safe use of the unit and they understand the resulting risks. Children must not play with the unit.
Cleaning or user maintenance must not be carried out by unsupervised children.

Protection against contact

MiniVent M1/100/120 F mini fans do not require protection guards, since they meet the requirements from
DIN EN 60335-2-80 section 20.101.

Motor protection

The motors of the MiniVent M1/100/120 F have thermal contacts, which are wired in series with the coil and
switch off automatically and restart after cooling.
Type overview MiniVent M1/1 . . F
M1/100 F with automatic humidity control
M1/120 F with automatic humidity control

Technical data

M1/100 F
Impeller [mm]
Ø 92
Alternating current
1~
Voltage/frequency
230 V, 50 Hz
Power consumption [W]
9/5
Rated current [mA]
0.06/0.04
Flow volumes [m 3 /h]
90/75
M1/120 F
Impeller [mm]
Ø 111
Alternating current
1~
Voltage/frequency
230 V, 50 Hz
Power consumption [W]
13/10
Rated current [mA]
0.09/0.08
Flow volumes [m 3 /h]
170/150
Electrical supply line
Protection category
Protection class
Weight approx. [kg]
Speed [1/min]
Electrical supply line
Protection category
Protection class
Weight approx. [kg]
Speed [1/min]
3
NYM-O 3 x 1.5 mm²
IP45 (water jet protection)
II
0.8
2650/2250
NYM-O 3 x 1.5 mm²
IP45 (water jet protection)
II
1.05
2350/2050