Herunterladen Inhalt Inhalt Diese Seite drucken

Optional: Installing The Tray - clage Zip HydroTap G4 BCS 160/175 Gebrauchs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für Zip HydroTap G4 BCS 160/175:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Zip HydroTap
®
G4 BCS100/75 und G4 BCS160/175
4. Installation
B ( 2 : 1 )
6
5
4
Gas bottle with
self closing valve
Gas bottle with
hand weel
6
5
4
Cut out a 10 mm slot for
the bolt
Fastening
Drain
Hole needed for tray
bolt
pipe bend
View from below
Note: Additional ventilation must be ensured if the temperature in the base
unit exceeds 35°C.
1. Position the undersink unit as close to the tap as possible.
2. Connect the water inlet to the angle valve (not supplied). Use the flexible hose
supplied to make this connection.
3. Connect the tap hoses to the undersink unit. Ensure there is a constant fall from the
tap down to the undersink unit. Trim the hoses to avoid loops and kinks. The hoses
must not be lengthened.
a. Connect the red marked silicone hose to the boiling water connection.
b. Connect the unmarked silicone hose to the steam connection.
c. Connect the Y adapter to the steel connecting pipe of the tap.
d. Connect both the cold water connection and the sparkling water connection of the
undersink unit to the free ends of the Y adapter. First trim the plastic hoses to the
3
2
required length and fit the supplied pipe insulation over them.
4. Connect the signal leads of the tap and the undersink unit. Attach the plug
connection at a location away from any water splashes.
5. Position the carbon dioxide gas bottle upright against a wall within reach of the gas
connection hose.
6. Install the gas bottle holder at the location where the carbon dioxide bottle is to
stand so that it can be secured against toppling over.
Please note that the room where a carbon dioxide gas bottle is placed must
have a minimum room volume of 38 m
7. Secure the gas bottle in an upright position to the gas bottle holder.
8. Connect the undersink unit to the pressure reducer for the gas bottle using the
braided hose supplied.
9. Connect the pressure reducer to the gas bottle:
a. Gas bottle with self closing valve: Turn the pressure adjusting screw on the
pressure reducer anticlockwise as far as it will go (no pressure). Then quickly screw
DATUM
Name
16.07.2014
ruecker
Gezeichnet
Kontrolliert
the gas bottle into the pressure reducer, as far as it will go.
Norm
Zeichnung Gasflaschenkopf
Status
Änderungen
DATUM
Name
3
2
b. Gas bottle with hand wheel: Turn the pressure adjusting screw on the pressure
reducer anticlockwise as far as it will go (no pressure). Then connect the pressure
reducer to the gas bottle. Tighten the union nut moderately tight.
Note: The carbon dioxide gas bottle must always be used in the upright posi-
tion to ensure that the pressure reducer operates correctly and thus ensure the
safety of the unit.
Note: The carbon dioxide gas bottle must not be exposed to heat or to direct
sunlight. Please do not exceed the maximum ambient temperature of 35°C.
Provide cooling if necessary.
35 mm hole
for tap

Optional: Installing the tray

The tray (article number: 4100-44111) is an accessory which can be used to install the
tap independently of a kitchen sink.
1. Ensure that a water supply, a drain, a socket fitted with at least a 10 A fuse and
enough room for the undersink unit are all available at the tray installation location.
2. Place the template supplied over the tray installation location.
3. Cut out the holes as indicated on the template.
recess 108 mm
4. Insert the tray. Place the plastic spacer between the worktop and the tray at the
35 mm hole. Working from below, fasten the tray to the threaded rod using the
1
F
E
D
C
B
A
1
A2
1
24
for every kg of bottle capacity.
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Zip hydrotap g4 bcs 100/75

Inhaltsverzeichnis