5. Using the Tap
'Install'
The steps that are necessary when using the unit for the first time can be viewed again
for maintenance purposes.
Flush filter – place the end of the hose located at the filter in a collecting container and
open the isolating valve on the hose before starting to flush the filter.
Reset filter – resets the filter consumption data.
Boiling point calibration – the unit determines the boiling point, which depends on the
atmospheric pressure at the installation location, and adjusts accordingly.
Booster – settings for operation of an additional instantaneous water heater to preheat
the hot water. A technical modification has to be made to the unit in order to connect up
a booster.
CO
flush – air and water inside the carbonizer are flushed out with carbon dioxide to
2
ensure that the carbonizer operates correctly. Wait about 10 seconds and then touch
'Stop' to stop CO
flushing.
2
Light sensor calibration – the light sensor on the tap can be calibrated for the light
conditions at the installation location. This is necessary to ensure that the Sleep mode
energy-saving function operates correctly. Shield the tap from direct sunlight during
calibration.
'Service'
A special password specific to the unit is needed in order to access the Service menu.
Please contact Central Customer Service.
'Password'
A user password can optionally be set to lock the 'Settings' menu and prevent
unauthorised persons from altering the settings. The password should be 4 digits long.
'Radio'
N/A.
'Set'
Date/time – set the time and the time format.
Temperature – set the water temperatures.
Filter – enter the filter data in order to calculate the remaining filter capacity.
Energy saving – the unit's heating function and chilling function can be disabled when
the unit is not in use, to reduce the energy demand. Alternatively, the boiling water
temperature can be reduced during Sleep phases for a shorter warm-up time when the
unit is used again.
• Sleep mode automatically reduces the energy demand according to use or to the
ambient light.
• The time switch reduces the energy demand according to the time set. The date and
time must be correctly set on the unit for this to operate correctly.
Safety – the Safety button can be enabled to prevent boiling water being dispensed
accidentally. This can be done either on the tap itself (refer to section XYZ) or via the
menu. Scald Protection can also be enabled, for instance to prevent children from
dispensing boiling water.
• To dispense boiling water when the Safety button is enabled, press the red lever and
at the same time press the Safety button on the tap.
• To dispense boiling water when Scald Protection is enabled, press the Safety button
three times in succession. Boiling water can then be dispensed for 30 seconds.
Dispensing time – pull the lever on the tap forward and set the dispensing time.