3.
auTOrizEd usE
Non-authorized use of the solenoid valve Type 5281
EV may be a hazard to people, nearby equipment
and the environment.
•
The device is designed to control, shut off and meter
neutral media up to a viscosity of 21 mm
•
Provided the cable plug is connected and installed
correctly, e.g. Bürkert Type 2508, the device satisfies
protection class IP65 in accordance with
DIN EN 60529 / IEC 60529.
•
During use observe the authorized data, the operat-
ing conditions and conditions of use specified in the
contract documents, on the rating plate and in the
operating instructions, as described in the chapter
entitled "6.Technical Data".
•
Correct transportation, correct storage and installation
and careful use and maintenance are essential for reli-
able and faultless operation.
•
Use the device only as intended.
english
4
4.
basic safETy
insTrucTiOns
These safety instructions do not make allowance for any
•
contingencies and events which may arise during the
installation, operation and maintenance of the devices.
•
local safety regulations – the operator is responsible for
observing these regulations, also with reference to the
installation personnel.
Danger – high pressure!
•
Before loosening the pipes and valves, turn off the
pressure and vent the pipes.
Risk of electric shock!
•
Before reaching into the device or the equipment,
switch off the power supply and secure to prevent
reactivation!
•
Observe applicable accident prevention and safety
regulations for electrical equipment!
Risk of burns/risk of fire if used for a prolonged
switch-on time through hot device surface!
•
Keep the device away from highly flammable substances
and media and do not touch with bare hands.
english
6
All manuals and user guides at all-guides.com
/s.
2
3.1.
predictable misuse
•
The device may only be used in the explosion-protected
area if an appropriate additional identification is attached
to the rating plate.
•
Do not put any loads on the housing (e.g. by placing objects
on it or standing on it).
•
Do not make any external modifications to the device
housings. Do not paint the housing parts or screws.
3.2.
restrictions
If exporting the system/device, observe any existing
restrictions.
Risk of injury due to malfunction of valves with
alternating current (AC).
Sticking core causes coil to overheat, resulting in a
malfunction.
•
Monitor process to ensure function is in perfect working
order!
Risk of short-circuit/escape of media through leaking
screw joints.
•
Ensure seals are seated correctly!
•
Carefully screw valve and connection lines together!
General hazardous situations.
To prevent injury, ensure that:
•
the system cannot be activated unintentionally.
•
Installation and repair work may be carried out by
authorized technicians only and with the appropriate
tools.
•
After an interruption in the power supply or fluid sup-
ply, ensure that the process is restarted in a defined or
controlled manner.
Type 5281 EV
english
5
5
english
7
7