Continuation
Maximum Surrounding Temperature (sandwich version):
Electronic
α
INV M
2 1.10
α
INV M
4 0.55
CONDITIONS OF ACCEPTABILITY:
Use - For use only in complete equipment where the acceptability of the
combination is determined by Underwriters Laboratories Inc.
1. These drives are incomplete in construction and have to be attached to an
external heatsink in the end-use. Unless operated with the heatsink as
noted in item 2 of the conditions of acceptability below, temperature test
shall be conducted in the end-use.
2. Temperature test was conducted with drive installed on aluminum heatsink,
overall dimensions and ribs shape as outlined below:
3. Suitability of grounding for the combination of drive and heatsink needs to
be verified in accordance with the end-use standard.
4. Temperature test was not conducted on models INV MD 4. Suitability of
drive - heatsink combination shall be determined by subjecting to
temperature test in the end-use.
Continuation on the next page
Betriebsanleitung INVEORα | DOC01464507 | 2014-09 | V1.00DE
Overall heatsink
dimensions
(150x27x210) mm
(150x27x210) mm
Surrounding
50° C
60° C
Suffix
Gx3
Gx3
139