Technical data

Appliance cat. II 2H3+
Type of gas
Burner
NATURAL GAS
auxiliary
(methane)
semi-rapid
G20
20 mbar
triple crown
Liquid petroleum
auxiliary
gas (LPG)
semi-rapid
G30-G31
30/37 mbar
triple crown
Burner
Auxiliary
Semi-rapid
Rapid
Triple crown
The use of larger pots than those specified can cause excessive overheating of the knobs and top.
Franke declines any liability for damage due to such incorrect use.
Total heat capacity: see dataplate on the bottom of the hob.
Air necessary for combustion: 2 m
Power supply voltage 220/240 V 50-60 Hz.
The appliance complies with the following EEC Directives:
– 90/396/EEC (Gas):
– 73/23/EEC dated 19/02/73 (Low Voltage);
– 89/336/EEC dated 03/05/89 (Electromagnetic Compatibility);
– 93/68/EEC dated 22/07/93 as amended.
18
All manuals and user guides at all-guides.com
Injector
marking
(1/100 mm)
72
97
rapid
115
140
50
65
rapid
85
91
Table of recommended pans
3
/h per kW of installed power - see dataplate.
Total rated
Heat
heat
capacity
capacity
reduced
in kW
in kW
1,000
0,380
1,750
0,440
3,000
0,800
3,300
1,600
1,000
0,380
1,750
0,440
3,000
0,800
3,300
1,600
Ø Pan in cm
from Ø 8 to Ø 14
from Ø 14 to Ø 20
from Ø 22 to Ø 24
from Ø 24 to Ø 28
Rated
consumption
3
0,095 m
/h
3
0,167 m
/h
3
0,286 m
/h
3
0,314 m
/h
73 g/h
127 g/h
218 g/h
240 g/h