Herunterladen Diese Seite drucken

By-Count Function; Accumulation Function; Battery Maintenance - Mettler Toledo Mini-Tiger Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
GB
METTLER TOLEDO
automatically.
If there is still no key operation and weight change 15 minutes after power saving status occurred, the scale will be
turned off automatically. This function can be enabled or disabled through setting of the softswitch (group 1, step
4: "Automatic Power Off").

By-Count function*

X
By-Count function is used to calculate the price of non-weighing items.
1) Enter deal quantity (1-99), press By-Count key, then enter the deal price.
2) Press enter key. The scale is now ready for by-count operation. The by-count cursor* is illuminated.
3) Enter the quantity to be sold, the scale will display the total price.
4) Press clear key to return the scale to weighing mode.

Accumulation Function*

+
Perform a transaction as described in straight weighing, by-count or tare mode sections.
Press the accumulation key. The total price will be added to the accumulated total. The illuminated cursors will point
to "TOTAL*" and "ADD*". The weight display will show message "totAL", the unit price display will show the number
of accumulations and the total price display will show the accumulated total price.
Repeat the above two steps until all desired transactions are accumulated.
There are three ways to return the scale back to the normal weigh mode:
1: Pressing the clear key to clear an accumulator, and return to weighing mode.
2: Press tare key to tare and back to weighing mode.
3: Press numeric key to enter new price and return to weighing mode.
Press accumulation key to recall accumulation when total price is zero or total price field is blank.
* These functions and cursors are not available in the scale to EU countries.

Battery Maintenance

Rechargeable lead-acid battery
If charging kit is installed, the scale can charge the lead-acid battery (6V/5Ah). To charge a lead-acid battery, connect
the scale to the external power supply. The battery will be charged regardless the scale is on or off.
It usually takes not more than 12 hours to charge the battery to full capacity depending on the voltage of the battery.
If the battery is has been deep-discharged, a prolonged charging time is required to bring the battery back to full
capacity.
There are two battery cursors, one is
, and the other is
. Cursor
is lit to indicate the battery capacity is full
(-)
and current power source is power supply, and it flashes to indicate that battery is being charged. Cursor
is lit
(-)
to indicate that current power source is battery, and it flashes to indicate that voltage of the battery is lower than the
required.
The scale shows "L Bat" in the weight window and stop weighing when the cursor
begins blinking, and the scale
(-)
will be turned off automatically about 10 seconds later. In this case, please charge the batteries.
If the unit is plugged into the wall outlet when battery power is used, the power source will automatically switch to
the wall transformer. And when the AC power is off, power source will automatically switch to battery.
Notice
The battery should be recharged at least every 5 months regardless it is used or not. After a long time storage, e.g.
over 3 months, it is desired to cycle (charge/discharge) the battery 3 times to let it restore to full capacity.
When replacing the battery, pay much attention to the poles. The positive (+) terminal must be connected to the red
connector and the negative (-) terminal must be connected to the black connector. If connected wrongly, the battery
will be damaged.
Mini-Tiger
8

Werbung

loading