AERMEC MODUCONTROL Bedienungsanleitung Seite 72

Elektrische regelvorrichtung
Vorschau ausblenden Andere Handbücher für MODUCONTROL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Code
Code
Alarm
Pre-alarm
37
137
40
140
41
141
42
142
43
143
44
144
45
145
46
146
47
147
51
151
54
--
55
155
--
156
57
157
58
158
59
159
60
160
61
161
62
162
63
163
64
164
65
165
66
166
67
167
68
168
69
169
70
170
71
171
72
172
73
173
74
174
75
175
76
176
77
177
78
178
79
179
72
EN
IMDCFJ. 12.05 6343841_03
Causes
DC Bus over-voltage
PFC Converter Fault
Error in the PFC module
Over current in acceleration mode
Overload
Over-current at constant speed
Over current in deceleration mode
Compressor not connected
correctly
No communication
Cooling fin temperature sensor
error
Anomalous condition
Cycle reverse valve faulty
Water inlet high temperature
Cycle reverse due to high
temperature of the pressing line
gas
Reading error of the DHW control
board remote probe.
Outdoor air temperature probe
reading error
Inlet water probe
no condenser
(ONLY WRL)
Output water probe
no condenser
(ONLY WRL)
Over-current
Compressor motor overload
Over-voltage
Under-voltage
Drive overheating
Drive underheating
Hardware over-current
Compressor overheating
Reserved
CPU error
Default parameters
DC bus ripple
No communication between invert-
er and uPC
Drive temperature sensor fault
Self-configuration failed
Inverter drive disabled
Motor phases error
Cooling fan
Inverter faulty
Speed fault
Notes
(code APY 6)
Software error (code APY 9)
Software error (code APY 10)
(code APY 11)
Software error (code APY 12)
Software error (code APY 13)
(code APY 14)
(code APY 15)
(code APY 16)
Protection frequency against over-current and overheating
reduced. (code APY 20)
The cycle reverse valve could be faulty or broken. (see
8.4)
The water inlet temperature has exceeded the set_install-
er (H) parameter value. Probable boiler presence on
same plant. At the third intervention of the pre-alarm, the
machine goes into alarm mode and blocks
This pre-alarm indicates the intervention of defrosting
due to cycle reverse without having respected the times
between cycle reverses. Cycle reverse has been triggered
by the pressing line gas high temperature partialisation
threshold being exceeded, set_factory (6)-set_factory (4)
= default 130°. This pre-alarm does not cause compressor
stop and does not have a limited number of interventions
This pre-alarm indicates a remote probe fault or a commu-
nication problem with the DHW control board. The alarm is
only active if the parameter (0)=2 or the parameter (8)=4 in
the menu with password = 30
This pre-alarm indicates an outdoor air temperature probe
fault when the DCP is present or the machine is in heat
pump mode.
This pre-alarm indicates a condenser inlet water tempera-
ture probe fault
This pre-alarm indicates a condenser outlet water tem-
perature probe fault
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter
Carel Inverter