Herunterladen Inhalt Inhalt Diese Seite drucken

Filling; Diagnostics And Maintenance; Common Errors - Mettler Toledo IND500x Kurzanleitung

Wägeterminal
Vorschau ausblenden Andere Handbücher für IND500x:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

Filling

Manual Filling

Diagnostics and Maintenance

Common Errors

Overcapacity
Terminal cannot execute commands because the weight on the scale is over the calibrated capacity.
The weight display shows blanked condition:
Under Zero
Terminal cannot execute commands because the weight is under the current captured zero. The weight
Blanking
display will show an under zero condition:
If motion is detected when a command is received, the IND500x will wait for a no- motion condition. If a
Motion
stable (no motion) weight condition is reached, the command is executed. If a no-motion state cannot be
reached, the command is aborted and a "Scale In Motion" error displays.
If pushbutton zero is enabled and the operator presses the ZERO scale function key, these common errors
Failure to Zero
may occur:
Zero Failed-Range: Gross weight outside the programmed zero range
Zero Failed-Net Mode: zero failed because scale is in net mode
Scale In Motion: zero failed due to motion on scale
If EEE is shown on display, the terminal has not captured a zero reference at power-up
Failure to Print
When an operator attempts to use the print function, these common errors could occur:
No Demand Output: print failed due to missing Demand Output connection
Scale In Motion: print failed due to motion on scale
Print Not Ready: print interlock has not been reset