Disposal
6
Disposal
Dispose of the product in accordance with the applicable rules and regulations.
This product must not be disposed of as household waste. This is indicated by the ad-
jacent symbol. You can return this product to Dräger free of charge. For information
please contact the national marketing organisations and Dräger.
7
Technical data
Standard
Ports
Max Distance
Data Rates
Isolation
LED
Power
Temperature
Humidity
EMI Compliance
Dimensions
Weight
Mechanical Fixing:
24
ISO 11898 / ISO.IEC 11801
1 x CAN 2.0
1 x RS485
1 x RS232
CAN: 5.000 m for 10K bps
CAN: 25 m for 1M bps
RS 485 Modbus RTU side: 1200 m for 115K bps
CAN: from 10K up to1M bps
Modbus: up to 115K bps
>2000 V DC
1 x Power indicator
2 x Signal indicator
12...35 V DC 200 mA
8...24 V AC; 50/60 Hz;200 mA
Operating: -30 °C to +70 °C (-22 °F to +158 °F)
Storage: -40 °C to 80 °C (-40 °F to +176 °F)
Operating:10 % to 80 %, non-condensing
Storage: 5 % to 90 %, non-condensing
EN 61000-6-2
FCC part 15 of Class A
120x23x107 (DxWxH)
200 g approx
DIN 35 mm Rail mounting
Dräger REGARD 3900 Modbus Gateway V2.0