Care and maintenance

Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
• Unscrew the pump [2] from the tank. (Fig. 7)
• Dismantle the pump [2].
a) Unlock the piston rod with handle [13]. (Fig. 17)
b) Pull the piston rod with handle [13] out of the cylinder tube up to the stop and turn it
counterclockwise (Fig. 17)
c) Disconnect the piston rod with handle [13] and the cylinder tube [2]. (Fig. 17)
• Grease the O-ring [19] and the diaphragm [20]. (Fig. 18)
• Assemble the pump.
a) Push the piston rod with handle [13] into the cylinder tube. (Fig. 20)
b) Hold the cylinder tube [2] and strongly press in the guiding plug [14] with your thumb.
(Fig. 20)
c) Pull the piston rod with handle [13] up to the stop down and turn it clockwise (Fig. 20)
► The guiding plug [14] snaps in.
• Lock the piston rod with handle [13] and screw the pump [2] into the tank [1]. (Fig. 9)
• Take the hose [4] with the discharge filter [34] out of the tank and clean the discharge
filter under running water. (Fig. 24)
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
Unless otherwise specified, we recommend that an expert carries out an external
test every 2 years and an internal test every 5 years as well as a strength test every
10 years.
Faults
Use only original spare and accessory parts.
Fault
No pressure builds up in
the device
Liquid flows out of the
pump
No tank pressure
indication on the piston
pressure gauge, Safety
valves blow off too early.
The data and illustrations in these instructions for use are for orientation only and not
binding in any way. The manufacturer reserves the right to make changes or improvements
to the products if these are considered appropriate without having to notify customers
owning a similar model about this fact.
Cause
The pump is not screwed on
tightly.
O-ring [19] on the pump is
faulty.
Diaphragm [20] is defective.
Valve disc [23] dirty of defec-
tive.
Piston pressure gauge [16] is
defective.
10
Remedy
Screw the pump on tightly.
Replace the O-ring (Fig. 19).
Replace the diaphragm (Fig. 19).
Clean or replace the valve disc
(Fig. 21).
Replace the piston pressure
gauge (Fig. 26).