Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37
EN
8. Create the desired pressure in the tank. (Fig. 11)
+
The maximum pressure should not exceed 3 bar (43,5 psi) (red line on the piston
pressure gauge, Fig. 11). If the maximum pressure is exceeded, the safety valve will
engage and release the excess pressure.
9. Press the piston rod with handle [13] down and turn it counterclockwise. (Fig. 6)
► The piston rod with handle is locked.
Use
Observe the instructions in the section entitled "Safety".
1. Connect the plug-in coupling [15] of the water pressure tank with the plug-in nipple on
your device [29]. (Fig. 12)
2. Activate the ball valve [30]. (Fig. 12)
► The liquid starts to be supplied.
+
The amount of liquid can be regulated via the ball valve [30] on the device (e.g. drill).
3. If the pressure drops below 1 bar (14.5 psi), min. 0.5 bar (7.25 psi), pump again. (Fig. 11)
4. If the tank is empty, refill. (→ See chapter entitled "Preparation")

After Usage

Observe the instructions in the section entitled "Safety".
Never leave liquid in the device.
1. Hold the plug-in coupling [15] and pull its outer ring. (Fig. 12)
► The plug-in coupling [15] is disconnected from the plug-in nipple [29] on the device.
2. Pull up the red piston pressure gauge [16] until the tank is depressurized. (Fig. 5)
3. Lock the piston rod with handle [13]. (Fig. 6)
4. Unscrew the pump [2] from the tank and empty the tank. (Fig. 7)
5. Wipe off the device with a moist cloth.
6. For drying and storing the device, keep the tank [1] and pump [2] separate in a dry place
protected from sunlight and freezing temperatures (Fig. 16).
9
ENGLISH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis