1. Push the lock lever down to engage the parking
brake.
2. To disengage the parking brake, push the lock lever
up.
Vacuum gauge
The vacuum gauge shows the condition of the primary
filters. If the value on the vacuum gauge is 20 cmH
higher, it is necessary to clean the primary filters. Refer
To clean the primary filters on page 17 . If the value
to
on the vacuum gauge is 15 cmH
clean the primary filters, it is necessary to replace the
primary filters. Refer to
To replace the primary filters on
page 18 .
Pressure tank manometer
The pressure tank manometer shows the pressure in the
pressure tank. The air in the pressure tank cleans the
primary filters. The pressure is around 7 bar/100 PSI
during operation.
10
O or
2
O or higher after you
2

Water separator

The water separator removes dirt, oil and water from the
air.
To connect a secondary product
1. Connect the power plug of the secondary product to
an applicable power supply or to the product.
2. Make sure that the dust extraction hose between the
product and the secondary product is connected with
hose clamps and industrial tape.
3. Make sure that the dust extraction hose is in good
condition and can move freely.
To connect the product to a power
source
1. Connect the power plug of the product to a grounded
mains outlet or other power source.
2. Make sure that the mains voltage agrees with the
type plate on the product.
To start the product
1. Connect the dust extraction hose between the
product and the secondary product.
2. Connect the product to a power supply.
3. Set the ON/OFF switch to the ON position.
2061 - 002 - 19.04.2023