Herunterladen Inhalt Inhalt Diese Seite drucken

User Qualification - GOK DE 50/30 S Montage- Und Bedienungsanleitung

Vordruckregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

USER QUALIFICATION

ASSEMBLY, MAINTENANCE, SHUT-DOWN , REPLACEMENT,
RESTART, RESTORATION, TROUBLESHOOTING
START-UP, DISPOSAL,
Leak check
*Experts are particularly those who, on the basis of their training, knowledge and experience
gained during practical activity, guarantee that they carry out the inspection properly.
CONNECTIONS
More information about compression fittings can be found at
www.gok.de/datenblaetter/Schneidringverschraubungen/
Data sheet - Compression fittings.
ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage
during transport. ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
The installation of the pressure regulator takes place in the vehicle interior,
behind the associated shut-off valve or directly in front of a 30 mbar gas equipment system
(consumer equipment).
The installation of the pressure regulator outside / underneath the vehicle is not permitted.
Screw connections
If connections leak, there is a danger of explosion, fire or suffocation!
Gas may escape if the product is turned.
Do not turn the product after it has been installed and the connections have been
tightened.
Tighten connections only when they are not pressurised.
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!
Artikel-Nr. 01 451 99 a
Activity
Vordruckregler Typ DE 50/30 S
Inlet connector G.15 = RVS 8
Outlet connector H. 9 = RVS 8
Ventilation connections Ø 4 mm
Qualification
qualified personnel,
customer service
user and operator
expert*