Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS R254K-UUI-RH11-S4 Konfigurationsanleitung Seite 145

Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RH11-S4:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RH11-S4
Photoelectric Sensors
5
Primary Device Functions (continued)
5.4.2
Process Data (AdSS)
Object ID
Name
0x0038 (56)
ADSS 1
0x003E (62)
Teach IN
Tab. 5-8:
Switching profiles – process data
5.4.3
Process Data (LSSC)
Object ID
Name
0x003A (58)
LSSC 1
0x003B (59)
LSSC 2
0x003C (60)
LSSC 3
0x003D (61)
LSSC 4
0x003E (62)
Teach IN
Tab. 5-9:
Switching profiles – process data
5.4.4
ISDU (AdSS)
Name
SSC Parameter SP
SSC Configuration Logic
Teach-In Result
Tab. 5-10: Switching profiles – ISDU
SSC Parameter SP
This parameter represents the currently set switching point
(setpoint). The default setting is 0x03E8.
SSC Configuration Logic
With the help of this parameter, the switching logic of the
switching channel can be configured.
Value
Meaning
0x00 (0)
High Active
0x01 (1)
Low Active
Tab. 5-11: Switching profiles – SSC Configuration Logic
www.balluff.com
Index
Subindex
Access
0x0038 (56)
0
0x0039 (57)
0
0x003B (59)
0
Description
Switching logic High
Active
Switching logic Low
Active
Description
AdSS Switching signal channel
Manual teach-in trigger
Description
LSSC Switching signal channel 1
LSSC Switching signal channel 2
LSSC Switching signal channel 3
LSSC Switching signal channel 4
Manual Teach-in Trigger
Length
Data Type
RW
16 bits
IntT16
RW
8 bits
UIntT8
RO
8 bits
UIntT8
Direction
Output
Input
Direction
Output
Output
Output
Output
Input
Data
Default
Storage
Yes
0x03E8
(1000)
Yes
0x00
No
english
37
Inhaltsverzeichnis
loading

Inhaltsverzeichnis